Electrochemical Sensor Based Analysers for CO,NO,NO2, SO2, O2 and many more gases

SERIES 89 PORTABLE / FIXED POINT TOXIC GAS ANALYSERS THE INSTRUMENT - LOW COST DEPENDABLE & INDIGENOUS

TOXIC GAS ANALYSERS SERIES 89 accurately measure the concentration of a particular gas in parts per million (ppm). These analysers may be used as a DESK-TOP model or PANEL-MOUNTABLE. These toxic gas analysers use electrochemical sensors which have an enviable reputation for reliability, stability and rugged design having an electrical output linearly proportional to concentration level of the gas. Ambient air monitoring can be done continuously. Process gas may be monitored only under certain conditions and levels.

Electrochemical Sensor Based Analysers

Available Model : SERIES 89

Applications

These instruments find application in Process Control, Quality control and Safety in work areas of Factories and Research institutions

Features

One alarm audible & visual user settable with set point view. Alarm relay with NO, C, NC for on-line models.

Recorder output of 0-1 V & 4 to 20 mA for On-line models.

Power 220 VAC OR Rechargeable battery option available ( to be specified in order)

Portable models offered with INBUILT PUMP & FLOW INDICATOR option to draw sample gas.

Standard Specifications

Display 3 ½ LCD digital 12 mm High
Working Temperature 0 to 50 °C
Accuracy ± 2% at constant temperature
Size & Weight 195 x 98 x 155 mm deep & 1.5 Kg
Sensor Electrochemical life expectancy 2 Years for O2 & 3 Years for Toxic gases
Recorder O/P 0 - 1 V Recorder Output
Alarm Visual & audible, settable through range. Low battery alarm also.
Flow Indicator 0 - 3 l/m provided.
Gases and Ranges Instrument supplied with oxygen and temperature sensors, additional sensors available as per table below
GAS RANGE RESOLUTION
O2 0 - 25 % 0.1 %
CO 0 - 1000 ppm 1 ppm
H2S 0 - 100 ppm 0.1 ppm
SO2 0-20 or 1999 ppm 0.1 ppm
CL2 0 - 50 ppm 0.1 ppm
NO2 0 - 50 ppm 1 ppm
HCN 0 - 30 ppm 1 ppm
H2 0 - 1999 ppm or 2 % 1 ppm or 10 ppm
PH3 0 - 1 ppm 0.01 ppm
O3 0 - 1 ppm 0.01 ppm
NH3 0 - 100 ppm 1 ppm
HCL 0 - 30 ppm 1 ppm
ETO 0 - 20 ppm 0.1 ppm
PH3 0 - 1 ppm 0.01 ppm
PH3 0 - 1 ppm 0.01 ppm
PH3 0 - 1 ppm 0.01 ppm
NO 0 - 100 ppm 1 ppm
COCL2 0 - 1 ppm 0.01 ppm
N2H4 0 - 1 ppm 0.01 ppm
A3H3 0 - 1 ppm 0.01 ppm
OTHER GASES & RANGES ON REQUEST

Options

OPTIONS for PORTABLE instruments only * Internal pump with suction of 8" Hg Column and flow of 1.5 l/m
* Rechargeable 12 V battery with charger & Low Battery Alarm
Accessories * Carrying Case, battery charger, cal screw driver, tubing
OPTIONS for ON LINE instruments only Accessories * One potential free relay NO, C, NC 50 VA contact rating
* 4 - 20 mA recorder output
Panel mounting clamps
Instrument manual, mounting clamps, cal screw driver, tubing
OPTIONS for sensor mounting * Either internal with an internal pump OR in diffusion on instrument.
* 4 - 20 mA recorder output
* Externally on end of a cable in diffusion mode only