Rudimentary Low Cost PM10 Samplers
Available Models : PEM–RDS 1, PEM–RDS 1NL, PEM–RDS 2
Model Comparisons :
The various models differ from each other in the type of blower used and type of the electronic control module employed as shown in table below
| Model → Component / Device ↓ |
PEM-RDS 1 | PEM-RDS 1NL | PEM-RDS 2 |
| Compatible Blower | BL1 | NL1 | BT1 |
| Electronic Control Module Type | ECM 2 | ||
Electronic Control Modules are similar in all respects except the following
| Model → Component / Device ↓ |
ECM 1 | ECM 2 |
| Compatible Blower | BL 1 / NL1 | BT1 |
| Flow Setting Range | Not Available | 25% to 98% of max flow |
| Flow Control Mode | Not Available | Manual – Open Loop |
| Flow Control Accuracy | Not Available | 3% of set value |
Specifications and features common to ECM1 and ECM2
| LCD Display | 32 Character Alphanumeric LCD Module with blue backlit | ||
| Number of Keys | 7 | ||
| Real Time Clock (RTC) | Nil | ||
| Settable Sampling Start Delay Time | Settable Up to 99 Hrs. 59 Min. | ||
| Settable Sampling Time | Settable Up to 99 Hrs. 59 Min. | ||
| Electronic Time Totalizer Range (Cumulative Sampling Time) | Up to 99 Hrs. 59 Min. | ||
| Automatic Sampling Start / Stop Control |
Fully programmable electronic timer to automatically shut off system after preset time interval. | ||
| Additional sampling control facility | Nil | ||
| Cyclic Mode Programming | Nil | ||
| Flow Measurement Basis | Flow is inferred from differential pressure (Δp) across an exhaust orifice | ||
| Δp measurement device | U tube manometer mounted on the inside of the instrument Range: 0-32 cms | ||
| Flow inferring technique | From flow Vs Dp graph Calibrated for each orifice and manometer combination | ||
| Displayed Flow Range | Not Available | ||
| Digital Flow Display | Not Available | ||
| Volume Totalizer Range | N/A | ||
| Temperature Measurement (for STP correction) | Not available | ||
| Internal Memory for data storage | Not available | ||
| Parameters Stored in internal memory | Not applicable | ||
| Addition information stored in internal memory | Nil | ||
| Data Transfer to Pen Drive through USB port | Not available | ||
| PC Interface software | |||
| Safety Features | |||
Accuracy Specifications
| Model | PEM–RDS 1 | PEM–RDS 1NL | PEM–RDS 2 | |
| Flow Measurement Accuracy | ± 3% | ± 3% | ||
| Flow Control Accuracy | - | - | ||
| Time Measurement | +/- 1 minute over 24 hours | |||
General Specifications - Common to PEM–RDS 1, PEM–RDS 1NL, PEM–RDS 2
| Filter Holder | SS 304 to accommodate filter paper of 25 x 20 cm |
| Filter Media | Whatman GF/A or EPM – 2000 |
| Particulate Sampling | For PM10 (i.e <10µ ± 1µ) using size selective inlet at 1.13M3/Min For SPM (i.e. <100µ) with Gable Roof (optional) |
| Construction Material & Finish | Sturdy Powder Coated Aluminum |
Operating Environment
| Power | 230 V AC ± 10%, 50 Hz.( 110 V, 60 Hz Optional ) |
| Temperature | 5 to 50oC |
| Relative Humidity | Up to 95% non condensing |
Physical Characteristics
| Model | PEM–RDS 1 | PEM–RDS 1NL | PEM–RDS 2 |
| Size ( all dimensions in mm) |
510 x420 x 1230 | 450 x 380 1100 | 450 x 380 x 850 |
| Weight | 42 Kg | 45 Kg | 22 Kg |
Quick Selection Guide
The table here below lists the decision criteria and the relative score / rating of the various models for the same
HVAS Model → |
RDS 1 | RDS 1NL | RDS 2 | RDS 4 | RDS 4NL | RDS 5 | RDS 6 | RDS 6NL | RDS 7 | RDS 8 | RDS 8NL | RDS 9 | |||
| Initial Cost | Excellent | Good | Average | ||||||||||||
| Running Cost (savings) | Fair | Fair | Good | Fair | Excellent Daily savings of 2 Filter papers ( Rs. 400) |
||||||||||
| Maintenance Requirement | Average | Excellent | Poor | Average | Excellent | Fair | Average | Excellent | Fair | Average | Excellent | ||||
| Operator Skill Requirement | Poor ( Skilled Operators required) |
Good (Automatic Data Acquisition Skilled Operators Not required) |
Excellent Automatic Data Acquisition and versatile reporting Skilled Operators Not required |
||||||||||||
| Portability | Average | Poor | Good | Average | Poor | Good | Average | Poor | Good | Average | Poor | Excellent | |||
| Flow Setting | Poor | Fair | Poor | Fair | Poor | Excellent | |||||||||
| Flow Control | Poor | ||||||||||||||
| Flow Accuracy | Fair | Average | Excellent | ||||||||||||
| Flow Constancy | Poor | Good | Excellent | ||||||||||||
| Automatic Measurement Data Recording | Poor | Good | Excellent | ||||||||||||
| Data Transfer to PC | Absent | Excellent | |||||||||||||
| Data Transfer to USB Pen Drive | |||||||||||||||
| Versatile Report Generation and Storage | |||||||||||||||
| Circular Chart Plotting of Flow Data | |||||||||||||||
Score : Absent, Poor, Fair, Average, Good, Excellent
Recommendation for Selection of High Volume Air Sampler
| S. No. | Scenario | Recommended Model |
| 1 | Severe Funds Crunch, Skilled Operator(s) available | PEM-RDS 1, PEM-RDS 1NL |
| 2 | Limited Funds availability, skilled manpower not available | PEM-RDS 5 |
| 3 | Desire for best value for money | PEM-RDS 9 |
| 4 | For other situations | Study the quick selection guide and decide. |
| 5 | Still not able to decide | Contact Polltech |
Competition shortcomings
- Flow– Well type Manometer( calibrated for flow) Vs Digital Display
- No volume totalization
- No flow recording
- Data transfer
- Data recording
- Start / stop
- Cycling
- Power Interruption recording
- STP / operating condition flow
- Flow control accuracy
- inlet
Add-ons
| Size Selective Inlet for PM10 Sampling | By replacing Gable Roof with Size Selective Inlet, this instrument can be transformed into a PM10 High Volume Sampler ie for lower size particulate concentrations , sampling of particulates < 10µ |
| Standard Ambient Gaseous Sampling Equipment | This basic add-on with icebox cooling allows the HVS to be utilized for sampling of upto four gaseous pollutants in addition to particulates which is the primary function of the equipment. |
| Thermoelectric Cooled Ambient Gaseous Sampling Equipment | This advanced add-on with thermo electric cooling allows the HVS to be utilized for sampling of upto four gaseous pollutants in addition to particulates which is the primary function of the equipment. |
Accessories and Consumables
- Voltage Stabilizer
- Filters of various media and sizes
- Chemical Reagent Kits
Related Services
You may also be interested in
- Flow Calibration Standard Range2 ( For Gaseous Sampling Add-on)
- Flow Calibration Standard Range5
Related Products
You may also be interested in
- PM10 High Volume Sampler
- Ambient Fine Dust Sampler
- Low Flow PM10/2.5 Sampler
- PUF Samplers
- Personal Air Sampler
- Dust Fall Jar