PUF2 - Polyurethane Foam Sampler
Helping you measure the toxic organic compounds in ambient air.
A sampling instrument that enables measurement of particulates and PCBs and PAH present in the air by entrapping them in Polyurethane Foam as per US EPA Method TO 9A
Available Model : PEM-PUF 2
A PUF Sampler simultaneously collects suspended airborne particulates as well as traps airborne organic vapors such as Pesticides, Polychlorinated bi phenyls-PCBs, Dioxin, Furan and Polycyclic Aromatic Hydrocarbons(PAHS) etc.

Applications :
- Routine Monitoring by air monitoring networks
- Compliance Monitoring in industrial areas
- Vehicular Pollution Monitoring in urban areas
- Monitoring Stations for ISO Compliance
- VOC Monitoring
- Fugitive gas monitoring
- Chemical, Petrochemical, Paint, Cosmetics etc
- Demos and Operation Trainings.
- Evaluative Studies
- Health Impact Studies
Physical Design Highlights
A PUF Sampler comprises a sampling head; a suction blower; a flow measuring device, a flow control device and an Electronic control Module. All these components and assemblies are housed in a sturdy cabinet.
The sampling head is a dual chambered aluminum container which houses both the filtering systems.
The upper chamber supports the airborne particulate filter media in a circular filter holder.
The lower chamber encompasses a glass cartridge which contains the Polyurethane Foam for vapor entrapment.
This dual chambered sampling module is designed for easy access to both upper and lower media. The threaded lower canister is removable with the cartridge intact for immediate exchange. Filter support screens and module components are equipped with gaskets providing a leak proof seal during the sampling process.
Salient Features :
- Meets requirements of EPA Method, T09A
- Accurate electronic volumetric flow control system.
- Wide flow range of 160 to 280 LPM
- Time based multiple sampling programs.
- Data logging for more than one sample runs.
- User Interface comprising LCD module and keypads for sample run setting.
- Simple setting up of sampling periods.
- Compact lightweight brush type blower for PUF 1
- Ultra-efficient, long life brushless, noiseless blower motor for PUF 2
- Automatic supply voltage monitoring and shut down facility for preventing instrument damage.
- Durable Weather-proof high quality anodized / powder coated aluminum cabinet.
Model Comparison
The three models mainly differ in the type of blower used and size of the enclosure
Feature | PEM-PUF2 | ||
Blower Type | Brushless, Noiseless AC Blower | ||
Size | 800 x 370 x 300 mm | ||
Weight | 38 Kg. |
Sampling Specifications
Pollutants Sampled | Particulates: dioxins, PCBs, Pesticides etc. Vapours : VOCs |
Sampling Head | Dual Chamber – upper chamber for particulates; lower chamber for VOCs |
Particulate collection media | 102 mm Round Quartz Filters (QMA4) – supported in a suitable filter holder |
VOCs collection media | PUF / XAD cartridge – housed in a removable glass cartridge |
Sampling Inlet for SPM | Gable Roof Model PEM-PUFX |
Sampling Inlet for PM10 | Size Selective Inlet PEM-PUFX-10 |
Cabinet Material | Powder coated Aluminum |
EPA method complied | TO 4A, TO 9A, TO 13A |
General Specification
Model → Specs. ↓ |
PEM-PUF-2 - 10µ |
Display | 32 character (2 lines x 16 character) backlit LCD Module. |
Keys | 6 Nos.. |
Real Time Clock (RTC) | Provided for Setting Delay Time and Sampling Time |
Delay Time | Programmable with Real Time Clock |
Sampling Time | Programmable upto 199 hrs. 59 mts. with Real Time Clock |
Electronic Time Totalizer | Upto 199 hrs. 59 mts. |
Automatic Sampling Control | Fully programmable electronic timer to automatically shut off system after preset time interval. Facility for programming ON / OFF Time in cyclic mode. |
Additional sampling control facility | Timer stops on no flow or very low flow |
Cyclic Mode Programming | Programming ON / OFF Time in cyclic mode |
Flow Measurement Basis | Flow is inferred from differential pressure (dp) across an exhaust orifice |
Exhaust Orifice D P measuring device | Pressure sensor |
Flow inferring Technique | Computed programmatically |
Constant Flow Control mode | Variable Frequency Drive |
Flow Control Accuracy | Within 2% of set value irrespective of dust load and main voltage variation. |
Flow Range | 160 to 280 LPM |
Volume Totalizer Range | Upto 999.9 M3 STP Corrected and operating conditions |
Temperature Measurement ( for STP correction ) |
Solid State Temperature Sensor |
Internal Memory for Data Storage | Capable of storing data pertaining to 10 samples |
Parameters Stored in internal memory | Sampling time, volume, minimum, maximum and average flow, the minimum & maximum ambient temp. |
Additional information stored in internal memory | Average flow, Constant Flow Volume, Non Constant Flow Volume with respective time stamps, log of power interruptions with details on durations and time |
Data Transfer to Pen Drive | USB port: ECM functions as Host and Pen Drive as device |
Windows based PC Interface | USB port: PC functions as Host and ECM as device |
PC Interface software | Windows based Software includes facility to acquire and save data from control module including flow data and power interruptions for further processing and plotting flow data in circular chart format indicating flow variation over 24 Hrs. It also facilitates programming all sampling parameters including Start and Stop time etc. |
Safety Features | Automatic Stoppage of Sampling due to under voltage, over voltage, low flow and high Flow conditions |
Blowers Types | Brushless, Noiseless AC Blower |
Power Supply | 170 to 270 V AC, 1 Phase, 50 Hz |
Accuracy Specifications
Flow Measurement Accuracy | ± 3 % |
Flow Control | Within 2% of set Value with Constant Flow Controller using Variable Frequency Drive irrespective of dust load & mains voltage variation. |
Operating Environment
Temperature | 5 to 500oC |
Relative Humidity | Upto 95% non condensing |
Accessories and Consumables :
- Quartz Microfiber filter paper
- PUF Cartridge 75mm
- Empty Glass Cartridge for PUF with SS Screen
- Teflon caps for sealing glass cartridges
- Silicone Gasket
- Transportation Container for storing PUF Cartridges
Related Products :
- High Volume Air Sampler PEM-HVS
- High Volume PM10 Sampler
- Ambient Fine Dust Sampler
- Low Flow PM10 Sampler Model PEM-LFAS10/2.5