Rudimentary Low Cost SPM Samplers

SPM HVAS is basically used for collecting SPM which comprises particles of AED less than 100µ. This is achieved by incorporating as the sampling inlet a Gable Roof, fabricated as per US EPA / CPCB specifications.

By replacing the Gable Roof with Size Selective Inlet, the samplers can also be used for collection of particles less than 10µ and gets transformed into a PM10 High Volume Sampler.

We manufacture a range of models of High Volume Air sampler to suit various applications and budgets. The models are distinguished from one another in respect of the technological sophistication in flow measurement and control and also in blower model employed for generation of flow.

Our Low Cost samplers Models PEM–HVS 1, PEM–HVS 1NL, PEM–HVS 2 utilize the classical methods of flow measurement and indication.

  • Flow is inferred from differential pressure (Δp) across an exhaust orifice
  • Δp is measured by a U tube manometer mounted on the inside of the instrument Range: 0-32 cms
  • Flow is inferred from flow Vs Δp graph calibrated for each orifice and manometer combination
  • Explicit on-line flow indication is not provided

Models PEM–HVS 1, PEM–HVS 1NL, PEM–HVS 2 are simple no-frill samplers and lack sophistication of our mid range and advanced models as indicated below

  • No internal memory for storing results
  • No Data transfer facility.
  • No volume totalizing capability

Physical Design Highlights:

High Volume Air Sampler consists of a high-capacity blower, a filter to collect suspended particles and a means for measuring the flow rate.

Suspended particles in the air are sampled at sampling rate between 1.1 to 1.6 m3/min through the side openings of the Gable roof and are collected on a 203 x 254 mm filter paper.

Salient Features :

  • Microprocessor based Electronic Control Module
  • Alphanumeric 32 character LCD Module
  • Electronic Timer Cum Time Totalizer
  • Settable Delay & Sampling Time
  • Continuous Duty Blowers
  • Orifice Plate at exhaust complies with USEPA.
  • Gaseous sampling attachment as add on for all models.
  • Can be morphed to a PM10 sampler by replacement gable roof with SSI.

Available Models : PEM –HVS 1, PEM–HVS 1NL, PEM–HVS 2

Model Comparisons :

The various models differ from each other in the type of blower used and type of the electronic control module employed as shown in table below

Model →
Component / Device ↓
PEM-HVS 1 PEM-HVS 1NL PEM-HVS 2
Compatible Blower BL1 NL1 BT1
Electronic Control Module Type
ECM 1
ECM 2

Electronic Control Modules are similar in all respects except the following

Model →
Component / Device ↓
ECM 1 ECM 2
Compatible Blower BL 1 / NL1 BT1
Flow Setting Range Not Available 25% to 98% of max flow
Flow Control Mode Not Available Manual – Open Loop
Flow Control Accuracy Not Available 3% of set value

Specifications and features common to ECM1 and ECM2

LCD Display 32 Character Alphanumeric LCD Module with blue backlit
Number of Keys 7
Real Time Clock (RTC) Nil
Settable Sampling Start Delay Time Settable Up to 99 Hrs. 59 Min.
Settable Sampling Time Settable Up to 99 Hrs. 59 Min.
Electronic Time Totalizer Range (Cumulative Sampling Time) Up to 99 Hrs. 59 Min.
Automatic Sampling
Start / Stop Control
Fully programmable electronic timer to automatically shut off system after preset time interval.
Additional sampling control facility Nil
Cyclic Mode Programming Nil
Flow Measurement Basis Flow is inferred from differential pressure (Δp) across an exhaust orifice
Δp measurement device U tube manometer mounted on the inside of the instrument Range: 0-32 cms
Flow inferring technique From flow Vs Dp graph Calibrated for each orifice and manometer combination
Displayed Flow Range Not Available
Digital Flow Display Not Available
Volume Totalizer Range N/A
Temperature Measurement (for STP correction) Not available
Internal Memory for data storage Not available
Parameters Stored in internal memory Not applicable
Addition information stored in internal memory Nil
Data Transfer to Pen Drive through USB port Not available
PC Interface software
Safety Features

Accuracy Specifications

Model PEM–HVS 1 PEM–HVS 1NL PEM–HVS 2
Flow Measurement Accuracy ± 3% ± 3%
Flow Control Accuracy - -
Time Measurement +/- 1 minute over 24 hours

General Specifications - Common to PEM–HVS 1, PEM–HVS 1NL, PEM–HVS 2

Filter Holder SS 304 to accommodate filter paper of 25 x 20 cm
Filter Media Whatman GF/A or EPM – 2000
Particulate Sampling For PM10 (i.e <10µ ± 1µ) using size selective inlet at 1.13M3/Min
For SPM (i.e. <100µ) with Gable Roof (optional)
Construction Material & Finish Sturdy Powder Coated Aluminum

Operating Environment

Power 230 V AC ± 10%, 50 Hz.( 110 V, 60 Hz Optional )
Temperature 5 to 50oC
Relative Humidity Up to 95% non condensing

Physical Characteristics

Model PEM–HVS 1 PEM–HVS 1NL PEM–HVS 2
Size
( all dimensions in mm)
510 x420 x 1230 450 x 380 1100 450 x 380 x 850
Weight 42 Kg 45 Kg 22 Kg

Quick Selection Guide

The table here below lists the decision criteria and the relative score / rating of the various models for the same

HVAS Model →
Decision Criterion ↓

HVS 1 HVS 1NL HVS 2 HVS 4 HVS 4NL HVS 5 HVS 6 HVS 6NL HVS 7 HVS 8 HVS 8NL HVS 9
Initial Cost Excellent Good Average
Running Cost (savings) Fair Fair Good Fair Excellent
Daily savings of 2 Filter papers ( Rs. 400)
Maintenance Requirement Average Excellent Poor Average Excellent Fair Average Excellent Fair Average Excellent
Operator Skill Requirement Poor
( Skilled Operators required)
Good
(Automatic Data Acquisition
Skilled Operators Not required)
Excellent
Automatic Data Acquisition and versatile reporting
Skilled Operators Not required
Portability Average Poor Good Average Poor Good Average Poor Good Average Poor Excellent
Flow Setting Poor Fair Poor Fair Poor Excellent
Flow Control Poor
Flow Accuracy Fair Average Excellent
Flow Constancy Poor Good Excellent
Automatic Measurement Data Recording Poor Good Excellent
Data Transfer to PC Absent Excellent
Data Transfer to USB Pen Drive
Versatile Report Generation and Storage
Circular Chart Plotting of Flow Data

Score : Absent, Poor, Fair, Average, Good, Excellent

Recommendation for Selection of High Volume Air Sampler

S. No. Scenario Recommended Model
1 Severe Funds Crunch, Skilled Operator(s) available PEM-HVS 1, PEM-HVS 1NL
2 Limited Funds availability, skilled manpower not available PEM-HVS 5
3 Desire for best value for money PEM-HVS 9
4 For other situations Study the quick selection guide and decide.
5 Still not able to decide Contact Polltech

Competition shortcomings

  • Flow– Well type Manometer( calibrated for flow) Vs Digital Display
  • No volume totalization
  • No flow recording
  • Data transfer
  • Data recording
  • Start / stop
  • Cycling
  • Power Interruption recording
  • STP / operating condition flow
  • Flow control accuracy
  • inlet

Add-ons

Size Selective Inlet for PM10 Sampling By replacing Gable Roof with Size Selective Inlet, this instrument can be transformed into a PM10 High Volume Sampler ie for lower size particulate concentrations , sampling of particulates < 10µ
Standard Ambient Gaseous Sampling Equipment This basic add-on with icebox cooling allows the HVS to be utilized for sampling of upto four gaseous pollutants in addition to particulates which is the primary function of the equipment.
Thermoelectric Cooled Ambient Gaseous Sampling Equipment This advanced add-on with thermo electric cooling allows the HVS to be utilized for sampling of upto four gaseous pollutants in addition to particulates which is the primary function of the equipment.

Add-ons

Size Selective Inlet for PM10 Sampling

By replacing Gable Roof with Size Selective Inlet, this instrument can be transformed into a PM10 High Volume Sampler ie for lower size particulate concentrations , sampling of particulates < 10µ

Standard Ambient Gaseous Sampling Equipment

This basic add-on with icebox cooling allows the HVS to be utilized for sampling of upto four gaseous pollutants in addition to particulates which is the primary function of the equipment.

Thermoelectric Cooled Ambient Gaseous Sampling Equipment

This advanced add-on with thermo electric cooling allows the HVS to be utilized for sampling of upto four gaseous pollutants in addition to particulates which is the primary function of the equipment.

Consumables

Filters of various media and sizes, Chemical Reagent Kits for Gaseous Sampling Attachments

Related Products

You may also be interested in

  • PM10 High Volume Sampler
  • Ambient Fine Dust Sampler
  • Low Flow PM10/2.5 Sampler
  • PUF Samplers
  • Personal Air Sampler
  • Dust Fall Jar

Accessories and Consumables

  • Voltage Stabilizer
  • Filters of various media and sizes
  • Chemical Reagent Kits

Related Services

You may also be interested in

  • Flow Calibration Standard Range2 ( For Gaseous Sampling Add-on)
  • Flow Calibration Standard Range5

Related Products

You may also be interested in

  • PM10 High Volume Sampler
  • Ambient Fine Dust Sampler
  • Low Flow PM10/2.5 Sampler
  • PUF Samplers
  • Personal Air Sampler
  • Dust Fall Jar