Metal Emissions Sampling Equipment
Facilitates measurement of metal emissions per US EPA Method 29
Available Model : PEM-MES 1-X
Applications :
Measurement of metal emissions per US EPA Method 29
Physical Design Highlights :
PEM-MES 1-X consists of a set of glass nozzles, a heated glass lined probe ( model PEM-HGLP 3 ), a heated filter box (model PEM-HFB2), an insulated PTFE sample transport tube and a sample collection equipment consisting of 6 or 7 glass impingers in an impinger box. The metering system for iso-kinetic sampling can be either be a manual kit ( PEM-SMK 10) or automatic kit (PEM SMS-4). The sample collection module can also be provided as add-on for an existing EPA method 5 sampling train.
Salient Features :
- Compliant with US EPA Method 29
- Can be combined with a Method 5 train
- Set of Seven Glass Greenburg-Smith Impingers
- Leak Free Spherical Joints
- Thermally Insulated Cold Box
Specification :
Equipment Item | Specifications |
Impinger Train | Seven Greenburg-Smith impingers of 240 ml capacity. 1st Knock-out with short stem, 2nd and 3rd with standard tip, 4th empty, 5th and 6th for Mercury and 7th with silica gel. Fittings: Leak-free spherical ground glass joints |
Connections External | Push fit Unions suitable for 12 mm OD tube |
Gas Temperature Measurement | Mercury in Bulb Thermometer / Digital Thermometer |
Impinger Box | Light weight thermally insulated wooden / aluminum Box |
Connections - External | Push fit Unions suitable for 12 mm OD tube |
Dimension | 20(W) x 43(L) x 35(H) CM. |
Weight | 6.5 Kg |
Related Products
- Automatic Stack Monitoring System : Model PEM – SMS 4
- Manual Stack Monitoring Kit : Model PEM – SMK 10B, PEM – SMK 10B
- Heated Sampling Probes : Model PEM - HGLP 3,PEM - HTLP 3, PEM - HSLP 3
- Volatile Organic Sampling System : Model PEM – VOSS 1
- Nitrogen Oxides (NOx) Sampling Equipment : Model PEM - NOS 1-X
- Metal Emissions Sampling Equipment : Model PEM - MES 1-X
- PM10 Sampling Equipment : Model PEM - STPM10-X
- PM2.5 Sampling Equipment : PEM - STPM2.5-X
- Standard Stack Gaseous Sampling Equipment : Model PEM - SSCIB 1-X